Nuclear Engineering and Plant Performance Wikis
Welcome to the central link to the wiki pages available from EPRI's Nuclear Engineering and Plant Performance Department.
EPRI's Nuclear Engineering and Plant Performance Department is comprised of three research programs:
- Plant Reliability and Resilience (PRR) Program - provides research supporting reliable and resilient operations of components, systems, and the nuclear plant, as a whole. This work covers mechanical, electrical, and I&C and addresses maintenance, engineering, and programmatic guidance and best practices.
- Risk and Safety Management (RSM) Program - provides research addressing Probabilistic Risk Analysis (PRA/PSA), External Hazards, and Thermal-Hydraulic applications for nuclear plants.
- Operating Plant Initiatives (OPI) - includes major project initiatives that the plant may undertake during plant life such as Plant Modernization, Longterm Operations (LTO), and Power Uprates (PUR).
Links to individual wikis developed by each of these programs are provides below. The search function above can be used to search across all of these wikis.
Plant Reliability and Resilience (PRR)
The reliability and resilience of plant systems and components is critical to the safe and effective operation of all nuclear plants. The Plant Reliability and Resilience (PRR) Program encompasses a diverse set of research activities related to the mechanical, electrical, and instrumentation and control components and systems in use at nuclear power plants, along with the maintenance and engineering processes and programs that manage this equipment. As of 2024, EPRI’s Plant Reliability and Resilience Program includes all the research formally delivered by EPRI’s Nuclear Maintenance Application Center (NMAC), Plant Engineering (PE) Program, and Instrumentation and Control (I&C) Program and can be categorized into:
- PRR - Nuclear Maintenance / Active Components
- PRR - Balance of Plant (BOP) / Passive Components
- PRR - Electrical
- PRR - Instrumentation and Control (I&C)
- PRR - Equipment Reliability (ER) and Related Processes
- PRR - Procurement Processes
PRR - Nuclear Maintenance / Active Components
Access: Member Only
EPRI 3D applications demonstrate the disassembly, reassembly, inspection and operation of specific power plant components. The applications consist of single mode or dual mode meaning they can be executed as a desktop application on a desktop/laptop computer and/or as a virtual reality (VR) application using a VR head-mounted display (HMD), such as the HTC VIVE.
Access: Member Only
The CBM Wiki is a comprehensive page for all Condition Based Maintenance (CBM) technologies with focus on Acoustics, Infrared, Lubrication, and Vibration technologies. CBM stories such as Lube Notes, Vibe Notes and others are excellent sources of case histories and provide technical references for solving practical plant/industry issues. Links to active EPRI reports are included as well as past meeting proceedings and materials.
Access: Member Only
The purpose of this wiki is to gather all the FLEX/portable equipment related documents into one easily accessible location for members who have interest/responsibility in/for FLEX/portable equipment . This wiki is the storage location for past Instant Benchmarking Requests (IBRs), industry best practice documents and anything else generated by the FLEX Industry Working Group.
Hoisting, Rigging, and Crane User Group
Access: Member Only
The HRCUG wiki serves as central resources for information, best practices, and research related to hoisting, rigging, cranes, and material handling within EPRI’s HRCUG program. EPRI’s work in these areas focuses on Hoisting, Rigging, and Cranes Users Group and Lifting, Rigging, and Material Handling.
Maintenance Engineering Fundamentals
Access: Member Only
The MEF wiki provides basic technical knowledge, expertise, and skills required to become a maintenance engineer at a power generation facility. The scope encompasses all forms of power generation such as nuclear, gas, and fossil. The term maintenance engineer is used to include component engineers, plant engineers, maintenance specialists, technical support engineers, and others that direct or influence maintenance activities at a facility.
Access: Member Only
Electronic work packages (eWPs) have become a primary innovation vehicle for integrating work activities with basic plant workflow process and information systems currently used in the work management process. The EPRI NMAC recognizes the potential benefits that eWPs can provide and has promoted industry collaboration to drive this initiative since 2013. This Wiki site was created to assist utilities with technical content needed to drive eWP success at the site.
Access: Member Only
Terry turbines used in the Reactor Core Isolation Cooling (RCIC) and Auxiliary Feedwater (AFW) systems are covered in this wiki. Basic system level information and turbine specific information is discussed. EPRI reports are referenced and live linked when appropriate.
Access: Member Only
The Valve wiki provides basic entry level information related to common valve and actuators found in the nuclear industry. Descriptions are provided within as well as basic design and maintenance related information. EPRI technical reports are referenced within and include live links for quick access downloads.
PRR - Balance of Plant (BOP) / Passive Components
Access: Member Only
The Condenser Wiki Site contains content from the Comprehensive Condenser Resource, Main Condenser Integrity Assessment Guide, and Condenser Application and Maintenance Guide, along with material from pertinent heat exchanger references. The material is organized by topic and enable users with a single, searchable, and easily accessible site dedicated to the topics of the main condenser. Because the Condenser Wiki is updated when new research or experience is available, the site should be beneficial for indoctrination of newer engineers and scientists as well as a resource for experienced professionals.
Access: Member Only
This Wiki provides a consolidated source of information related to the topic of selective leaching degradation. Summarized information associated with this degradation mechanism, as well as NDE techniques, are included within. References and links are also provided to relevant EPRI research reports, as well as past EPRI meeting materials associated with the topic.
PRR - Electrical
Access: Member Only
The PEER Cable Aging Wiki covers selected content from Instrument Cable, Low Voltage Power & Control Cable, and Medium Voltage Insulations Cable Polymer Handbooks, including Industry Background and History, Basic Cable Structure, Materials Used, Installation Process, Degradation Mechanisms, and Walkdown Inspections.
Transformer & Switchyards Wiki
Access: Member Only
This wiki provides insights into power transformer operation maintenance responsibilities, and basic fundamentals of switchyard design and equipment applications. Information includes operating experience at nuclear plants, vendor input, and other industry experience for transformers, as well as basic information and insight for personnel assigned to engineering, operational, planning, or maintenance responsibilities associated with switchyard equipment.
PRR - Instrumentation and Control (I&C)
Access: Public
Facilitates access and knowledge transfer by housing information relating technical topics within the PRR - Instrumentation and Control (I&C) area. It is intended to be an informative resource that is updated continuously with new information produced or managed by EPRI.
PRR - Equipment Reliability (ER) and Related Processes
Equipment Reliability Working Group (ERWG)
Access: Member Only
The purpose of this wiki is to gather all the Equipment Reliability Working Group (ERWG) meeting materials and member surveys into one easily accessible location for members. This wiki page will store past member benchmarking surveys and meeting material generated for the semi-annual ERWG meetings.
Maintenance Rule User's Group (MRUG)
Access: Member Only
The purpose of this wiki is to gather all the MRUG meeting materials and member surveys into one easily accessible location for members. This wiki page will store past member benchmarking surveys and meeting material generated for the semi-annual MRUG meetings. Documents and other materials produced by the MRUG will be summarized within this Wiki and links will be provided from this page. This page is also intended to complement EPRI's Maintenance Rule User's Group Page and Collaboration pages.
Single Point Vulnerability (SPV)
Access: Member Only
This wiki is based on EPRI Report 3002029784, Single-Point Vulnerability Process Guide, Revision 2 and provides the detailed steps needed to develop, implement, and maintain an SPV program. A comprehensive SPV program will ensure that SPVs are identified and dispositioned appropriately to reduce the likelihood of an unplanned reactor scrams.
PRR - Nuclear Procurement Processes
EPRI Procurement Information Center (EPIC)
Access: Member Only
EPIC contains technical information related to nuclear procurement and supply chain, research focus areas within the Nuclear Plant Engineering Program at EPRI. It’s organized by major activities in the procurement process. The activity-specific pages provide brief descriptions of each activity as well as links to EPRI guidance and training that is available for performing the activity, industry surveys relating to the activity, and related presentations that have been given at past JUTG meetings.
Risk and Safety Management (RSM)
Access: Member Only
The External Hazards Wiki organizes the nuclear industry's methodologies, regulatory guidance, and operating experience for external hazard assessment into a structured, navigable collection of references and document summaries. The wiki covers multiple hazard types, including high winds, flooding, wildfires, and compound events. This integrated approach provides a practical entry point for professionals new to the field while serving as a consolidated reference for experienced practitioners.
Access: Public
The Fire PRA Wiki summarizes a structured framework for the conduct of a Fire PRA analysis. This supports your fire risk analysis team by providing an introduction to EPRI 1011989 / NUREG/CR-6850, updated with the latest information. The methodology addresses a Fire PRA that focuses on a Level 1 PRA (Core Damage Frequency) with consideration of Large Early Release Frequency. Additional references to specific recommended practices are provided, which address each key aspect of the analysis.
Access: Member Only
The PRA Applications Wiki provides an introduction to the wide applications of PRA in the nuclear industry. This serves the needs of the global PRA community, providing a clear description, purpose, and rationale for each application. Both voluntary and regulatory PRA applications are described and this overview distinguishes those that require license-basis changes. References to more technical information provide a resource to expand your knowledge further.
Access: Public and Member
Knowledge of the methods used in in the U.S. nuclear industry is in many cases distributed amongst different entities with various degrees of information availability and communication. This wiki provides a centralized, publicly available industry catalog for PRA methods in use.
PRA Newly Developed Methods Wiki
Access: Public
With the issuance of Regulatory Guide 1.200, Revision 3 the US Nuclear Regulatory Commission (NRC) endorsed the concept of a “Newly Developed Method (NDM)” for use in Probabilistic Risk Assessments (PRAs). This Wiki shares information from previous evaluations within the industry specifically that have been provided to EPRI for inclusion in the Wiki. These evaluations of interest are those related to whether a PRA method is considered an NDM, and whether an NDM Peer review has been conducted to determine the technical adequacy of the method for inclusion in risk applications as necessary.
Access: Member Only
This PRA Software Guidance wiki provides recommendations and guidance for using the EPRI PRA software. The EPRI software is designed to be very flexible to support a variety of research in the creating and applying PRA models. In many cases, this diverse set of features can be confusing or can lead to creation of models that cause problems in subsequent applications. Although there is rarely a "best way" to create a PRA model, some techniques will make the software more efficient or enable certain features. This wiki is designed to share these insights with the users.
PRA Workforce Development Wiki
Access: Public
Outlines a plan to develop the PRA workforce by providing a recommended course outline. This allows users to develop a training plan as well as to review the references to PRA information and training courses available. This material can provide a PRA Engineer with a basis of knowledge for success and supplements the site-specific model training needed to be fully qualified.
Risk Analysis Methods and Tools for Advanced Reactors (RAMTAR)
Access: Public
Outlines past, present, and future research for advanced reactors by describing a wide range of risk analysis methods and tools that are applicable to various reactor designs, as well as providing references regulations, guidance, and research projects.
Access: Public
The seismic probabilistic risk assessment (SPRA) Wiki summarizes a structured framework for the conduct of an SPRA analysis. This wiki is intended to serve the needs of a seismic risk analysis team by describing a structured framework for conduct of the overall analysis, as well as providing references to specific recommended practices to address each key aspect of the analysis. The wiki provides overall guidance, with an emphasis on seismic hazard analysis, SPRA systems analysis, equipment list development, fragility guidance, human reliability analysis, and model development and quantification.
Access: Public
The Central and Eastern United States Seismic Source Characterization for Nuclear Facilities (CEUS-SSC) Project was conducted from April 2008 to December 2011 to provide the nuclear industry a new, regional seismic source model for use in conducting probabilistic seismic hazard analyses (PSHAs) for nuclear facilities.
Electronic SQUG (eSQUG) Database
Access: Member Only
This website, branded as eSQUG, is a compilation of this proprietary data, organized for easy use by licensed members. As this information is the intellectual property of EPRI, it is available only under license and may not be reproduced or disclosed to any unauthorized person or organization.
Access: Member Only
The Seismic Qualification Utility Group (SQUG) collects, evaluates, and facilitates the use of earthquake and testing experience data. Its mission is to maintain the validity of and to support and broaden the use of earthquake experience data as a cost-effective method for seismic qualification and fragility development.
Operating Plant Initiatives
Access: Member Only
EPRI’s Digital transformation Wiki was created for the purpose of having a centralized repository to link all of the research that EPRI does related to this topic.
Access: Public
This wiki is intended to provide a structured framework for presenting information relevant to extending the life of nuclear plants beyond their initial authorized or designed period both in the United States (US) and internationally.
Nuclear Plant Modernization Toolkit
Access: Member Only
The Plant Modernization Toolbox is meant to be a resource to facilitate decision making and execution of the modernization process at nuclear power plants (NPPs). The Toolbox includes a variety of tools and aids to assist NPPs to identify and evaluate cost savings from technology and process improvements.
Access: Public
The EPRI Operating Plant Initiatives (OPI) wiki serves as a central resource for the OPI program, providing access to program areas, technical resources, tools, and ongoing work supporting long-term plant operations and improvements.
Record of Revisions
| Number | Date | Description of Changes |
|---|---|---|
| 0 | 7/27/2021 | Initial Release |
| 1 | 12/10/2021 | Added PRA-NDM, NMAC-CBM, NMAC-FLEX |
| 2 | 4/1/2022 | Selective Leaching Added |
| 3 | 11/28/2022 | Condenser Wiki Added |
| 4 | 11/28/2022 | Seismic PRA Wiki Added |
| 5 | 4/27/2023 | Plant Reliability and Resilience, MRUG, ERWG Added |
| 6 | 8/22/2023 | SPV Added |
| 7 | 12/12/2023 | High Wind PRA and PRA Software Guidance Added |
| 8 | 12/20/2023 | Editorial revisions to reflect PRR and Plant Modernization Program structures |
| 9 | 7/26/2024 | RAMTAR Added |
| 10 | 8/6/2024 | I&C Wiki Added |
| 11 | 6/5/2025 | LTO Wiki Added |
| 12 | 3/12/2026 | Transformer & Switchyards Wiki Added |
| 13 | 11/19/2026 | PRA Workforce Development Wiki Added |































